link Formula molecular Weight Appearance melt Point boiling Point Density Solubility in H2O precise Mass Monoisotopic Mass
ClCu
98.99
Off-white powder
426° C (798.8° F)
1,490° C (2,714° F)
4.145 g/cm3
N/A
97.89845
97.898453 Da

Signal Word risk Statements peril Codes preventive Statements speed Point danger Codes safety Statements RTECS Number transfer Information WGK Germany GHS Pictograms
Danger
H302-H315-H318-H410
N/A
P273-P280-P305 + P351 + P338-P501
no applicable
N/A
N/A
GL6990000
UN 2802 8 / PGIII
3

*

*

*

SECTION 1. IDENTIFICATION

Product Name: Copper(I) Chloride

Product Number: all applicable American aspects product codes, e.g. CU1-CL-02, CU1-CL-03, CU1-CL-04, CU1-CL-05

CAS #: 7758-89-6

Relevant figured out uses that the substance: scientific research and development

Emergency telephone number:Domestic, north America: +1 800-424-9300International: +1 703-527-3887

SECTION 2. Risks IDENTIFICATION

Classification the the substance or mixtureClassification according to Regulation (EC) No 1272/2008GHS07Acute Tox. 4 H302 Harmful if swallowed.Hazards no otherwise classifiedNo data availableLabel elementsLabelling follow to Regulation (EC) No 1272/2008The substance is classified and labeled follow to the CLP regulation.Hazard pictograms


*

GHS07Signal wordWarningHazard statementsH302 Harmful if swallowed.Precautionary statementsP264 Wash thoroughly after handling.P270 perform not eat, drink or smoke once using this product.P330 rinse mouth.P301+P312 IF SWALLOWED: call a toxicity CENTER/doctor if you feel unwell.P501 Dispose that contents/container in accordance v local/regional/national/international regulations.WHMIS classificationE - Corrosive materialClassification systemHMIS ratings (scale 0-4)(Hazardous materials Identification System)HEALTHFIREREACTIVITY201Health (acute effects) = 2Flammability = 0Physical peril = 1Other hazardsResults of PBT and vPvB assessmentPBT:N/AvPvB:N/A

SECTION 3. COMPOSITION/INFORMATION ~ above INGREDIENTS

SubstancesCAS No. / substance Name:7758-89-6 Copper(I) chlorideIdentification number(s):EC number:231-842-9Index number:029-001-00-4

SECTION 4. An initial AID MEASURES

Description of an initial aid measuresIf inhaled:Supply patient through fresh air. If no breathing, provide artificial respiration. Save patient warm.Seek immediate medical advice.In situation of skin contact:Immediately wash with soap and also water; rinse thoroughly.Seek instant medical advice.In instance of eye contact:Rinse opened up eye for number of minutes under to run water. Consult a physician.If swallowed:Seek medical treatment.Information because that doctorMost important symptoms and effects, both acute and delayedNo data availableIndication of any immediate clinical attention and also special therapy neededNo data available

SECTION 5. FIREFIGHTING MEASURES

Extinguishing mediaSuitable extinguishing agentsProduct is not flammable. Use fire-fighting actions that fit the neighboring fire.Special hazards occurring from the problem or mixtureIf this product is associated in a fire, the adhering to can be released:Hydrogen chloride (HCl)Metal oxide fumeAdvice because that firefightersProtective equipment:Wear self-contained respirator.Wear completely protective impervious suit.

You are watching: What is the formula for copper i chloride

SECTION 6. ACCIDENTAL release MEASURES

Personal precautions, security equipment and also emergency proceduresUse an individual protective equipment. Save unprotected persons away.Ensure adequate ventilationEnvironmental precautions:Do not enable material to be released to the environment without official permits.Methods and also materials for containment and cleanup:Dispose that contaminated product as waste follow to section 13.Prevention of secondary hazards:No special steps required.Reference to various other sectionsSee section 7 for info on for sure handlingSee section 8 for information on an individual protection equipment.See ar 13 because that disposal information.

SECTION 7. HANDLING and STORAGE

HandlingPrecautions for for sure handlingHandle under dry protective gas.Keep container strict sealed.Store in cool, dry location in tightly closed containers.Ensure good ventilation in ~ the workplace.Prevent formation of dust.Information about protection against explosions and fires:The product is no flammableConditions for for sure storage, including any type of incompatibilitiesRequirements to it is in met through storerooms and receptacles:No unique requirements.Information about storage in one typical storage facility:Store away from oxidizing agents.Store away from air.Store away from water/moisture.Further information around storage conditions:Store under dry inert gas.This product is moisture sensitive.This product is waiting sensitive.Keep container tightly sealed.Store in cool, dry conditions in well-sealed containers.Protect native humidity and also water.Specific end use(s)No data available

SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Additional information about design of technological systems:Properly operation chemical fume hood designed for hazardous chemicals and having one average face velocity that at the very least 100 feet every minute.Control parametersComponents through limit values that call for monitoring at the workplace:Not required.Additional information:No dataExposure controlsPersonal protective equipmentFollow common protective and also hygienic techniques for dealing with chemicals.Keep far from foodstuffs, beverages and also feed.Remove all soiled and also contaminated clothes immediately.Wash hands before breaks and at the finish of work.Maintain one ergonomically appropriate working environment.Breathing equipment:Use perfect respirator when high concentrations are present.Recommended filter machine for quick term use:Use a respirator with type N95 (USA) or PE (EN 143) cartridges together a backup to design controls. Threat assessment must be performed to identify if air-purifying respirators are appropriate. Only use equipment tested and also approved under proper government standards.Protection the hands:Impervious glovesInspect gloves before use.Suitability that gloves need to be established both through material and also quality, the last of which might vary by manufacturer.Material of glovesNitrile rubber, NBRPenetration time the glove material (in minutes)No data availableEye protection:Safety glassesBody protection:Protective work-related clothing

SECTION 9. PHYSICAL and CHEMICAL PROPERTIES

Information on an easy physical and chemical propertiesAppearance:Form: flour or crystalsColor: No data availableOdor: No data availableOdor threshold: No data available.pH: N/AMelting point/Melting range: 430 °C (806 °F)Boiling point/Boiling range: 1490 °C (2714 °F)Sublimation temperature / start: No data availableFlammability (solid, gas)No data available.Ignition temperature: No data availableDecomposition temperature: No data availableAutoignition: No data available.Danger that explosion: No data available.Explosion limits:Lower: No data availableUpper: No data availableVapor pressure: N/ADensity at 20 °C (68 °F): 4.14 g/cm3 (34.548 lbs/gal)Relative densityNo data available.Vapor densityN/AEvaporation rateN/ASolubility in / Miscibility through Water in ~ 20 °C (68 °F): 0.12 g/lPartition coefficient (n-octanol/water): No data available.Viscosity:Dynamic: N/AKinematic: N/AOther informationNo data available

SECTION 10. STABILITY and REACTIVITY

ReactivityNo data availableChemical stabilityStable under recommended warehouse conditions.Thermal decomposition / problems to it is in avoided:Decomposition will not happen if used and also stored according to specifications.Possibility of hazardous reactionsNo dangerous reaction knownConditions come avoidNo data availableIncompatible materials:AirOxidizing agentsWater/moistureHazardous decomposition products:Metal oxide fume

SECTION 11. TOXICOLOGICAL INFORMATION

Information ~ above toxicological effectsAcute toxicity:Harmful if swallowed.LD/LC50 values that are appropriate for classification:Oral LD50 140 mg/kg (rat)Skin wake up or corrosion:May reason irritationEye irritation or corrosion:May cause irritationSensitization:No sensitizing impacts known.Germ cell mutagenicity:No impacts known.Carcinogenicity:EPA-D: no classifiable regarding human carcinogenicity: insufficient human and animal proof of carcinogenicity or no data are available.Reproductive toxicity:No impacts known.Specific target organ device toxicity - recurring exposure:No results known.Specific target organ device toxicity - solitary exposure:No results known.Aspiration hazard:No impacts known.Subacute come chronic toxicity:No impacts known.Additional toxicological information:To the best of our knowledge the acute and chronic toxicity the this problem is not totally known.Carcinogenic categoriesOSHA-Ca (Occupational security & health Administration)Substance is no listed

SECTION 12. Ecological INFORMATION

ToxicityAquatic toxicity:No data availablePersistence and also degradabilityNo data availableBioaccumulative potentialNo data availableMobility in soilNo data availableEcotoxical effects:Remark:Very toxicity for aquatic organismsAdditional ecological information:Do not permit product to reach groundwater, water courses, or sewage systems.Do not enable material to be released to the setting without official permits.Danger to drinking water if even little quantities leak right into the ground.Also poisonous because that fish and also plankton in water bodies.May reason long lasting harmful impacts to aquatic life.Avoid transfer into the environment.Very toxicity for aquatic organismsResults the PBT and vPvB assessmentPBT:N/AvPvB:N/AOther adverse effectsNo data available

SECTION 13. Disposal CONSIDERATIONS

Waste therapy methodsRecommendationConsult main regulations to ensure suitable disposal.Uncleaned packagings:Recommendation:Disposal need to be made according to main regulations.

See more: The Bond Angle In H2Se Is About:, What Are The Bond Angles Of Pf_3 And H_2Se

SECTION 14. EXPOSURE CONTROLS/PERSONAL PROTECTION

UN-NumberDOT, IMDG, IATAUN2802UN suitable shipping nameDOTCopper chlorideIMDGCOPPER CHLORIDE, marine POLLUTANTIATACOPPER CHLORIDETransport risk class(es)DOTClass8 Corrosive substances.Label8Class8 (C2) Corrosive substancesLabel8IMDGClass8 Corrosive substances.Label8IATAClass8 Corrosive substances.Label8Packing groupDOT, IMDG, IATAIIIEnvironmental hazards:Environmentally hazardous substance, solid; naval PollutantMarine pollutant (IMDG):Yes (P)Symbol (fish and also tree)Special precautions because that userWarning: Corrosive substancesEMS Number: F-A,S-BSegregation groupsAcidsTransport in mass according to Annex II the MARPOL73/78 and also the IBC CodeN/ATransport/Additional information:DOTMarine Pollutant (DOT):Yes (PP)Remarks:Special marking with the price (fish and tree).UN "Model Regulation":UN2802, Copper chloride, 8, III

SECTION 15. Regulation INFORMATION

Safety, health and also environmental regulations/legislation certain for the substance or mixtureNational regulationsAll components of this product are detailed in the U.S. Ecological Protection company Toxic Substances control Act chemical substance Inventory.All contents of this product are noted on the Canadian domestic Substances list (DSL).SARA section 313 (specific toxic chemical listings)7758-89-6 Copper(I) chlorideCalifornia Proposition 65Prop 65 - Chemicals recognized to cause cancerSubstance is not listed.Prop 65 - Developmental toxicitySubstance is no listed.Prop 65 - Developmental toxicity, femaleSubstance is not listed.Prop 65 - Developmental toxicity, maleSubstance is not listed.Information around limitation the use:For use just by technically standard individuals.Other regulations, limitations and prohibitive regulationsSubstance of very High issue (SVHC) follow to the with Regulations (EC) No. 1907/2006.Substance is not listed.The problems of limitations according to article 67 and Annex XVII the the Regulation (EC) No 1907/2006 (REACH) because that the manufacturing, place on the market and use have to be observed.Substance is no listed.Annex XIV of the reach Regulations (requiring Authorisation for use)Substance is no listed.Chemical security assessment:A Chemical safety Assessment has actually not been carried out.

SECTION 16. Various other INFORMATION